Condition Monitoring Excellence
Accessibility links:
Main navigation:
Debris to be analysed is placed in the SEM and bombarded with electrons which release X rays characteristic of the element that they hit. These X-rays are used to determine the elemental composition of the alloy.
This test covers the analysis of wear contaminants from oil wetted surfaces in the oil lubrications systems of turboprop, turbofan or APU engines.This is accomplished by analysing the residue obtained from flushing the oil filter in accordance with the method.
This is an in-house test for assessing filter debris, and determining its constituents.
Williams International procedure for oil filter analysis for the FJ44 engine and its derivatives.This is accomplished by analysing the residue obtained from flushing the oil filter in accordance with the method.