Condition Monitoring Excellence
Accessibility links:
Main navigation:
This test is used to determine fuel dilution as percentage by weight in lubricating oil.
Various standards of fuels (Diesel, Bio-Diesel and Gasoline) are prepared in various oil grades and injected onto a Gas Chromatography Column to create calibration curves. The unknown samples are injected and their readings are compared with the standards to calculate the fuel dilution.